<LOGO>
FM Transmitter Measurement Report
Created: 2025-01-16 16-28-07
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
6.3 kHz 5.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 69 kHz 15640 12,6726
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,0 dBr 4,64 dBr 5,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 69 kHz MIN: 11 kHz % above 76 kHz: 12,6726 Acquired: 2025/01/16 16.27.03 Total samples: 15640 Equivalent time: 0:13:02 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,7 dBr MIN: 3,0 dBr AVE: 4,64 dBr % above 12,2 dBr: 0,0 Last value: 5,3 dBr (2025/01/16 16.27.03) 16.14 16.16 16.18 16.20 16.22 16.24 16.26 0 2 4 6 Pm [dBr]